Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 192
Filter
1.
Article in English | LILACS-Express | LILACS | ID: biblio-1528861

ABSTRACT

This case report aimed to describe the importance of endodontic treatment in reducing infectious foci in patients with Eisenmenger syndrome (ES) and describe the characteristics of ES, so that the endodontist can safely treat these patients. A 57-year-old male with ES sought dental care complaining of dental pain. Irreversible pulpitis was diagnosed in tooth 37 and pulp necrosis in teeth 36, 34 and 31. Tests of prothrombin time (PT), activated partial thromboblastin time (APTT) and international normalized ratio (INR) were prescribed to evaluate the profile of coagulation using Marevan and antibiotic prophylaxis with amoxicillin. The endodontic treatments were performed. At the end, the patient reported no pain or discomfort in the teeth and improved masticatory function. The removal of oral infectious foci in patients with ES is important to reduce the risk of IE, which could seriously compromise the health and overall prognosis of the patient.


Este reporte de caso tuvo como objetivo describir la importancia del tratamiento endodóntico en la reducción de focos infecciosos en pacientes con síndrome de Eisenmenger (SE) y describir las características del SE, para que el endodoncista pueda tratar con seguridad a estos pacientes. Un hombre de 57 años con ES buscó atención dental quejándose de dolor dental. Se diagnosticó pulpitis irreversible en el diente 37 y necrosis pulpar en los dientes 36, 34 y 31. Se solicitaron pruebas de tiempo de protrombina (PT), tiempo de tromboblastina parcial activada (TTPA) y índice internacional normalizado (INR) para evaluar el perfil de coagulación utilizando Marevan y profilaxis antibiótica con amoxicilina. Se realizaron los tratamientos de endodoncia. Al final, el paciente no refirió dolor ni molestias en los dientes y mejoró la función masticatoria. La eliminación de focos infecciosos orales en pacientes con ES es importante para reducir el riesgo de EI, que podría comprometer gravemente la salud y el pronóstico general del paciente.

2.
J. res. dent ; 11(2): 25-31, Oct 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1513036

ABSTRACT

Aims: The aim was to evaluate the cyclic and torsional fatigue resistance among thermally treated NiTi rotary instruments with different design features.Materials and methods: Sixty instruments of three systems were used (n=20): TruNatomy 26.04 (TN 26.04), BassiLogic 25.05 (BL 25.05), and Flat File 25.04 (FF 25.04). The cyclic fatigue test (n=10) was performed to evaluate the time to fracture (s) and the number of cycles until failure (NCF). The torsion test was performed to evaluate the torque (N.cm) and maximum angular deflection until fracture (n=10). The fracture surface of each fragment was examined under a scanning electron microscope. The data were analyzed by Tukey's test (p<0.05).Results: BL 25.05 and FF 25.04 instruments had a higher number of cycles and time to fracture compared with TN 26.04 (p<0.05). TN 26.04 instruments showed lower torque to fracture.Conclusions: Based on the proposed objectives and the methodology used, TruNatomy 26.04 instruments present lower resistance to cyclic fatigue and torsional fatigue when compared to BassiLogic 25.05 and Flat File 25.04 instruments.

3.
Braz. dent. j ; 34(5): 36-42, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528022

ABSTRACT

Abstract Evaluate the shaping ability and preparation time using a pediatric motor-driven rotary instrumentation compared to other systems in resin prototypes of primary molars. Methods: Thirty specimens were scanned in micro-CT and divided into three groups according to the instrumentation type: pediatric motor-driven Sequence baby File (SBF); conventional motor-driven (Sequence Rotary File - SRF); manual K file. Instrumentation time was timed. After preparation, the specimens were scanned again. The pre- and post-instrumentation images were superimposed to measure the amount of root canal deviation and the resin remnant thickness. ANOVA followed by the Tukey test analyzed the comparisons between groups (p<0.05). Results: No statistically significant differences occurred in root canal deviation among groups (p>0.05). There were statistically significant differences in the comparison among root thirds (p<0.001) but without significant differences in the interaction group vs. root third (p>0.05). Both motor-driven instrumentations showed statistically greater weariness than manual instrumentation (p<0.001), without significant significant differences between SBF and SRF. Motor-driven instrumentation had a shorter working time than manual instrumentation (p<0.001). Conclusion: Pediatric motor-driven instrumentation demonstrated good outcomes in relation to root canal deviation and amount of remnant structure, with shorter instrumentation time. SBF can be a suitable alternative for endodontic instrumentation in primary molars.


Resumo Objetivo: Avaliar os resultados da instrumentação endodôntica e o tempo de preparo de lima odontopediátrica ativada por motor (Sequence Baby File- SBF) em canais de molares decíduos prototipados. Métodos: Trinta espécimes foram escaneados em micro-CT e divididos em três grupos de acordo com o tipo de instrumentação: mecanizada odontopediátrica (SBF); mecanizada convencional; lima K manual. O tempo de instrumentação foi cronometrado. Após o preparo, os espécimes foram escaneados novamente. As imagens pré e pós-instrumentação foram sobrepostas e a quantidade de desvio do canal radicular e a espessura de resina remanescente foram mensurados. Para as análises de comparações entre os grupos foram realizados teste ANOVA seguido do teste de Tukey (p<0,05). Resultados: Não ocorreram diferenças estatisticamente significativas entre os grupos no desvio do canal radicular (p>0,05). Houve diferenças estatisticamente significativas na comparação entre terços radiculares (p<0,001), mas sem diferenças significativas na interação grupo vs. terço radicular (p>0,05). A instrumentação mecanizada apresentou desgaste estatisticamente maior do que a instrumentação manual (p<0,001), sem diferenças estatísticas entre a SBF e a lima mecanizada convencional. A instrumentação mecanizada teve menor tempo de trabalho quando comparado a instrumentação manual (p<0,001). Conclusão: A instrumentação mecanizada odontopediátrica demonstrou bons resultados em relação ao desvio do canal radicular e quantidade de estrutura remanescente, com menor tempo de instrumentação. A SBF pode ser uma alternativa adequada para a instrumentação endodôntica em molares decíduos.

4.
J. res. dent ; 11(1): 7-13, May 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1513029

ABSTRACT

NiTi endodontic instruments for glide path are the most susceptible to fractures inside the root canal, mainly as a result of high torsional stress. Objective: The present study investigated the resistance to torsion and angular deflection of instruments destined for the glide path: ProGlider #16.02; T-File #17.02 and the MK Life #16.02. Materials and methods: Thirty rotating NiTi glide path instruments (n=10) with 25mm lengths were selected. The torsion test was performed based on ISO 3630-01 (1992). Three millimeters from the tip of the instruments, it was attached to a small load cell by a lever arm connected to the torsion shaft. Torsional strength and angular deflection were evaluated. Fracture surfaces were examined by scanning electron microscopy with magnifications of 1000x and 5000x in the cross section, and 50x in the lateral section. Statistical analysis was performed using the Kruskal-Wallis H test, followed by the Down's post hoc test. Results: The ProGlider instrument showed greater torsional strength (p<0.05) compared to the T-File (p<0.05) and MK Life (p<0.05), respectively. However, the T-File showed greater angular deflection (p<0.05) than the other groups tested. Conclusion: It can be concluded that the ProGlider instrument presented greater torque for the fracture, while the T-File instrument presented greater angular deflection.

5.
Braz. dent. j ; 34(1): 1-11, Jan.-Feb. 2023. graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420576

ABSTRACT

Abstract A continuous search for bioactive materials capable of supporting the replacement of damaged pulp tissue, with effective sealing potential and biocompatibility, has represented the attention of studies over the last decades. This study involves a narrative review of the literature developed by searching representative research in PUBMED/MEDLINE and searches in textbooks associated with the mechanism of action of bioactive materials (calcium hydroxide, mineral trioxide aggregate (MTA), and calcium silicate cements). The reflective analysis of the particularities of the chemical elements of these materials, considering the tissue and antibacterial mechanism of action, allows a better understanding of the characteristics and similarities in their tissue responses. Calcium hydroxide paste remains the antibacterial substance of choice as intracanal dressing for the treatment of root canal system infections. Calcium silicate cements, including MTA, show a favorable biological response with the stimulation of mineralized tissue deposition in sealed areas when in contact with connective tissue. This is due to the similarity between the chemical elements, especially ionic dissociation, the potential stimulation of enzymes in tissues, and the contribution towards an alkaline environment due to the pH of these materials. The behavior of bioactive materials, especially MTA and the new calcium silicate cements in the biological sealing activity, has been shown to be effective. Contemporary endodontics has access to bioactive materials with similar properties, which can stimulate a biological seal in lateral and furcation root perforations, root-end fillings and root fillings, pulp capping, pulpotomy, apexification, and regenerative endodontic procedures, in addition to other clinical conditions.


Resumo Uma busca contínua de materiais bioativos com capacidade de substituir o tecido pulpar danificado, com efetiva capacidade de selamento e biocompatibilidade, tem representado a atenção e foco de muitos estudos ao longo das últimas décadas. Este estudo envolve uma revisão narrativa da literatura desenvolvida por meio de pesquisas representativas encontradas no PUBMED/MEDLINE e pesquisas em livros didáticos associadas ao mecanismo de ação de materiais bioativos (hidróxido de cálcio, agregado de trióxido mineral (MTA) e cimentos de silicato de cálcio). A presente análise reflexiva das particularidades dos elementos químicos destes materiais bioativos, considerando o mecanismo de ação tecidual e antibacteriano, possibilita um melhor entendimento das características e similaridades no comportamento tecidual. A pasta de hidróxido de cálcio continua sendo a substância antibacteriana de escolha como medicação intracanal para o tratamento das infecções do sistema de canais radiculares. Este fato se deve a disponibilidade química de íons cálcio e hidroxila do hidróxido de cálcio aos tecidos, e a inibição enzimática bacteriana. Os cimentos de silicato de cálcio, dentre os quais inclui o MTA, apresentam uma resposta biológica favorável ao estímulo à deposição de tecido mineralizado nas áreas seladas e em contato com tecido conjuntivo. Este fato é decorrente da similaridade entre os elementos químicos, em especial devido a dissociação iônica, ao potencial estímulo de enzimas teciduais, e a contribuição com um meio alcalino decorrente do pH destes materiais. O comportamento dos materiais bioativos, em especial o MTA e os novos cimentos de silicato de cálcio na atividade de selamento biológico mostraram efetivos. A endodontia contemporânea atualmente conta com o potencial de materiais bioativos com propriedades análogas capaz de estimular o selamento biológico em perfurações radiculares laterais e de furca, em obturações radiculares, capeamento pulpar, pulpotomia, apicificação e procedimentos endodônticos regenerativos, além de outras condições clínicas.

6.
Braz. dent. j ; 34(1): 12-18, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420578

ABSTRACT

Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.


Resumo O objetivo deste estudo foi avaliar a influência da temperatura nas propriedades de torção (resistência à torção e deflexão angular) de dois instrumentos rotatórios experimentais de NiTi fabricados com secção triangu.ar e tratamentos térmicos Blue e Gold. Quarenta instrumentos experimentais de NiTi 25.06 com tratamento térmico Blue e Gold foram usados (n= 20). Foi avaliada a resistência torcional e a deflexão angular até a fratura na temperatura ambiente (21°C ± 1°C) e corporal (36°C ± 1°C). O teste torcional foi realizado nos 3 mm da ponta dos instrumentos de acordo com a ISO 3630-1. A superfície fraturada de cada instrumento foi observada pelo microscópio eletrônico de varredura (MEV). Os dados foram analisados por meio do teste t não pareado para a comparação inter e intragrupos e o nível de significância à 5%. Os resultados demonstraram que a temperatura corporal não afetou a resistência a torção e deflexão angular quando comparada com a temperatura ambiente (P>0.05). No entanto, na temperatura de 36°C o instrumento com tratamento térmico Blue apresentou menor deflexão angular quando comparado com o Gold (P<0.05). Não houve diferença significante entre os dois instrumentos em relação a resistência à torção. A temperatura corporal não modificou a resistência torcional dos instrumentos fabricados com tecnologia Blue e Gold. No entanto, os instrumentos com NiTi Blue apresentaram menor deflexão angular do que o Gold a 36°C.

7.
J. appl. oral sci ; 31: e20230222, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1514410

ABSTRACT

Abstract This study aimed to assess the self-reported levels of confidence and knowledge related to non-odontogenic pain among a group of Brazilian endodontists. Methodology A total of one hundred and forty-six endodontists affiliated with the Brazilian Society of Endodontics participated in the survey. The questionnaire, distributed via email or WhatsApp, contained inquiries designed to gauge self-perceived confidence and knowledge concerning non-odontogenic pain. The practitioners were categorized into four groups based on their self-reported familiarity with various orofacial pain types, classified as either sufficient or insufficient, and on their engagement in ongoing educational programs related to orofacial pain. Data were analyzed by Chi-Square Test and Fischer's exact test (p<0.05). Results Overall, self-reported confidence about non-odontogenic pain was high, especially for endodontists who considered their knowledge about orofacial pain sufficient, regardless of whether they had (71.1% - 97.8%) or not (35.7% - 96.4%) been continuously involved in education courses on orofacial pain. In general, self-reported knowledge about non-odontogenic pain was insufficient (0% - 42%), except in the question about how they would act in cases of pain that persists beyond the normal healing time after an endodontic procedure (70.6% - 81.9%). In general, endodontists are confident in their diagnosis and treatment of non-odontogenic pain. Nonetheless, this confidence did not correlate with a commensurate knowledge depth of. Thus, specialization courses in endodontics should highly consider training and qualifying these professionals in the diagnosis of non-odontogenic pain.

8.
J. appl. oral sci ; 31: e20230005, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1440411

ABSTRACT

Abstract Irrigation solutions might affect dentin surface characteristics and, consequently, endodontic sealers adhesion. Objective This study analyzed the effect of different final irrigation protocols on push-out bond strength (BS) of AH Plus to dentin seven days and 20 months after obturation. Scanning electron micrographs were obtained from the dentin surface of one sample/group after final irrigation. Methodology Canals of bovine incisors were instrumented and received final irrigation with (n=21): G1 - 2.5% sodium hypochlorite (NaOCl) + distilled water; G2 - 2.5% NaOCl + 17% EDTA; G3 - 2.5% NaOCl + 17% EDTA + 2.5% NaOCl; G4 - 2.5% NaOCl + 17% EDTA + 2% chlorhexidine (CHX); G5 - mixture 5% NaOCl + 18% etidronate (HEDP); and G6 - mixture 5% NaOCl + 10% tetrasodium EDTA (Na4EDTA). After irrigation, one root/group was split and images were obtained by scanning electron microscopy (SEM). The other 20 roots/group were filled with only AH Plus sealer. Three slices/root were used for push-out assessment seven days and 20 months after obturation. One-way analysis of variance and Tukey (α<0.05) were used to compare the results among experimental groups, and unpaired t-test (α<0.05) was used to compare the results of the same group over time. Results The photomicrographs showed that, excepting G1, all groups completely removed the smear layer from the samples. In G2 and G4, the opening of the dentin tubules enlarged. In G3, erosion was observed in the peritubular and intertubular dentin. Values of the BS in the seven days were G2=G3=G4=G5>G6=G1 and in the 20 months were G3=G5>G6=G4>G1=G2. G3, G5, and G6 presented values of BS in 20 months similar to the values of seven days (P>0.05). Conclusions The final irrigation protocols tested produced dentin surfaces with different characteristics. Only G3 and G5 presented high BS values that were stable over time.

9.
Braz. oral res. (Online) ; 37: e059, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439753

ABSTRACT

Abstract The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.

10.
Braz. j. oral sci ; 22: e238692, Jan.-Dec. 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1509506

ABSTRACT

Aim: This study investigated the influence in vitro of different sodium hypochlorite (NaOCl) agitation protocols associated or not with DualRinse (HEDP) on the temperature of the solution. Methods: Forty-eight premolars were instrumented and their apical third sealed to allow a closed irrigation system. The teeth remained immersed in a basin of warm water (37°C). The teeth were divided into the groups: G1 (NaOCl+Passive Ultrasonic Irrigation (PUI)), G2 (NaOCl/HEDP + PUI), G3 (NaOCl + EasyClean (EC)) and G4 (NaOCl/HEDP + EC). The canals were filled with the respective solutions and after 180 seconds the first temperature measurement was taken (T0). Then, the solutions were agitated, following the different protocols, for 60 seconds and a new measurement was performed (T60). The temperature was measured using a digital thermometer for type "K" sensors that was inserted into the middle third of the teeth. At the end of the measurements, the teeth were sectioned and prepared for scanning electron microscopy. The dentinal wall of middle third was graded according to the amount of debris and smear layer remaining on the walls. The results were analyzed using ANOVA test and Tukey's multiple comparisons (p<0.05). Results: G1 and G2 had an average increase in temperature of 1.1°C and 1.65°C, respectively (p>0.05). EasyClean caused a decrease in the temperature of the solutions in both groups, without a significant statistical difference with T0 (p>0.05). Regarding cleaning, it was only possible to observe clean dentinal tubules in the groups with the chelator. PUI discretely increased the temperature of the solution, regardless of the solution. The opposite effect was observed after activation with EasyClean. Conclusion: The association of NaOCl with a chelating agent promoted the cleaning of the dentinal tubules


Subject(s)
Root Canal Irrigants , Sodium Hypochlorite , Temperature , Ultrasonics , Microscopy, Electron, Scanning , Chelating Agents
11.
Braz. dent. j ; 33(6): 13-19, Nov.-Dec. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420565

ABSTRACT

Abstract Aim: To investigate whether foraminal widening performed at primary treatment has an effect on the amount of apically extruded obturator material during retreatment and to evaluate the sensitivity of cone beam computed tomography (CBCT) in detecting extruded obturator material. Methods: Forty palatal roots of maxillary molars were selected based on micro-CT and divided into two groups (n=20): with foraminal widening (WE) and without foraminal widening (NE). To standardize the apical foramen, all specimens were instrumented to the foramen using the Protaper Next system, up to instrument X3. The WE group was instrumented to the foramen up to instrument X5, and the NE group was instrumented 1 mm lower. The canals were obturated 1 mm below the apical foramen with gutta-percha and AH Plus and stored for 7 days at 37 °C and 95% humidity. Roots were fixed in microtubes filled with 1.5% agar gel. The obturation material was removed with Reciproc R50. Scans of the teeth and agar were performed using micro-CT and CBCT. Comparison between groups and between methods was performed using Mann-Withney test (p ≤0.05). Results: No statistical difference was found when comparing the extruded material between groups using micro-CT (p = 0.589) or CBCT (p = 0.953). CBCT measured a greater volume of extruded material than micro- CT (p = 0.0004). Conclusion: Foraminal widening had no effect on the extrusion of filling material during retreatment. The CBCT favored the evaluation of apically extruded filling material.


Resumo Objetivo: Investigar se o alargamento do foramen realizado durante o tratamento primário tem um efeito na quantidade de material obturador apicalmente extruído durante oretratamento e verificar a sensibilidade da tomografia computorizada de feixe cônico (TCFC) na detecção de material obturador extruído. Métodos: Quarenta raízes palatinas de molares superiores foram selecionadas de acordo com a microtomografia computorizada, e foram divididas em dois grupos (n=20): com alargamento do foraminal (CA) e sem alargamento do foraminal (SA). Para padronizar o forame apical, todas as amostras foram instrumentadas com o sistema ProTaper Next até ao instrumento X3 até o forame. O grupo CA foi instrumentado até ao instrumento X5 até o forame, e o grupo SA foi instrumentado 1 mm aquém. Os canais foram obturados 1 mm abaixo do forame apical com gutta-percha e AH Plus e armazenados durante 7 dias a 37 °C e 95% de umidade. As raízes foram fixadas em microtubos preenchidos com gel de ágar a 1,5%. O material obturador foi removido com Reciproc R50. Os escaneamentos dos dentes e do ágar foram realizados com micro-CT e CBCT. A comparação entre grupos e entre métodos foi realizada utilizando o teste Mann-Withney (p ≤0.05). Resultados: Não foi encontrada diferença estatística ao comparar o material extruído entre grupos utilizando o Micro-CT (p = 0,589) ou TCFC (p = 0,953). Foi medido um volume maior de material extruído com a TCFC do que com a Micro- CT (p = 0,0004). Conclusão: O alargamento foraminal não teve qualquer efeito na extrusão do material obturador durante o retratamento. A TCFC favoreceu a avaliação do material de obturador apicalmente extruído.

12.
Braz. dent. j ; 33(3): 47-54, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384034

ABSTRACT

Abstract The aim of this study was to investigate the physicochemical and biological properties of an experimental tricalcium silicate-based repair cement containing diclofenac sodium (CERD). For the physicochemical test, MTA, Biodentine and CERD were mixed and cement disc were prepared to evaluate the setting time and radiopacity. Root-end cavity were performed in acrylic teeth and filled with cements to analyze the solubility up to 7 days. Polyethylene tubes containing cements were prepared and calcium ions and pH were measured at 3h, 24h, 72h and 15 days. For the biological test, SAOS-2 were cultivated, exposed to cements extracts and cell proliferation were investigated by MTT assay at 6h, 24h and 48h. Polyethylene tubes containing cements were implanted into Wistar rats. After 7 and 30 days, the tubes were removed and processed for histological analyses. Parametric and nonparametric data were performed. No difference was identified in relation to setting time, radiopacity and solubility. Biodentine released more calcium ion than MTA and CERD; however, no difference between MTA and CERD were detected. Alkaline pH was observed for all cements and Biodentine exhibited highest pH. All cements promoted a raise on cell proliferation at 24h and 48h, except CERD at 48h. Biodentine stimulated cell metabolism in relation to MTA and CERD while CERD was more cytotoxic than MTA at 48h. Besides, no difference on both inflammatory response and mineralization ability for all cement were found. CERD demonstrated similar proprieties to others endodontic cements available.


Resumo O objetivo deste estudo foi investigar as propriedades físico-químicas e biológicas de um cimento reparador experimental à base de silicato de tricálcio contendo diclofenaco de sódio (CERD). Para o teste físico-químico, MTA, Biodentine e CERD foram manipulados e discos de cimentos foram preparados para avaliar o tempo de presa e a radiopacidade. Retrocavidades foram feitas em dentes de acrílico e preenchidas com cimentos para análise de solubilidade por 7 dias. Tubos de polietileno contendo cimentos foram preparados e os íons cálcio e o pH foram mensurados às 3h, 24h, 72h e 15 dias. Para o teste biológico, SAOS-2 foram cultivadas, expostas aos extratos de cimentos e a proliferação celular foi investigada pelo ensaio de MTT às 6h, 24h e 48h. Tubos de polietileno contendo cimentos foram implantados em ratos Wistar. Após 7 e 30 dias, os tubos foram removidos e processados para análises histológicas. Dados paramétricos e não paramétricos foram realizados. Nenhuma diferença foi identificada em relação ao tempo de presa, radiopacidade e solubilidade. Biodentine liberou mais íons de cálcio do que MTA e CERD; no entanto, nenhuma diferença entre MTA e CERD foi detectada. O pH alcalino foi observado para todos os cimentos e o Biodentine exibiu o pH mais alto. Todos os cimentos promoveram aumento na proliferação celular às 24h e 48h, exceto o CERD às 48h. Biodentine estimulou o metabolismo celular em relação ao MTA e CERD, enquanto CERD foi mais citotóxico do que MTA em 48h. Além disso, nenhuma diferença foi encontrada na resposta inflamatória e na capacidade de mineralização para todos os cimentos. CERD demonstrou propriedades semelhantes a outros cimentos endodônticos disponíveis.

13.
J. res. dent ; 10(2): 1-6, apr.-jun2022.
Article in English | LILACS, BBO | ID: biblio-1395871

ABSTRACT

Background: The aim of this study was to evaluate the cyclic fatigue and torsional fatigue resistance of three thermally treated rotary instruments, such as: Logic 2 25.05 (LOG 25.05), Edge Taper Platinum 25.06 (EDT 25.06) and ProTaper Gold 25.08 (PTG 25.08).Methods: A total of 60 rotary instruments of LOG 25.05, EDT 25.06 and PTG 25.08 were used (n=20). Cyclic fatigue tests were performed at 36°C using an artificial stainless steel canal with a 60ºangle and a 5-mm radius of curvature. The time (in seconds) and number of cycles to fracture (NCF) was recorded. The torsional test evaluated the torque and angle of rotation to failure at 3 mm from the tip according to ISO 3630-1. The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using one-way ANOVA and Holm-Sidak's tests for multiple comparison, the level of significance was set at 5%.Results: EDT 25.06 had highest cyclic fatigue resistance (time and NFC), followed by LOG 25.05 and PTG 25.08 (P<0.05). There were no significantly difference between LOG 25.05 and ETP 25.06 regarding the NCF (P>0.05). In relation the torsional test, the LOG 25.05 and ETP 25.06 presented similar torque (P>0.05). The PTG presented greater torque than the other groups (P<0.05). The PTG 25.08 presented the lowest angular rotation to fracture than the other groups (P<0.05). The SEM images demonstrated typical features of cyclic and torsional fracture.Conclusion: In conclusion, the LOG 25.05 and ETP 25.06 presented similar cyclic and torsional properties. The PTG 25.08 showed greater torsional strength.


Subject(s)
Humans , Endodontics
14.
J. res. dent ; 10(1): 14-19, jan.-mar2022.
Article in English | LILACS | ID: biblio-1378183

ABSTRACT

Introduction: This study aimed to evaluate the dentinal tubule penetration of an endodontic bioceramic sealer, Sealer Plus BC, after three final irrigation protocols. Methods: Thirty distobuccal roots of maxillary molars were selected. Root canal preparation was performed up to an #40.06 instrument (X1 Blue) under 2.5% sodium hypochlorite irrigation. Specimens were randomly divided into three groups (n=10), according to the final irrigation protocol: G-NaOCl (2.5% sodium hypochlorite + PUI), G-SS (0.9% saline solution + PUI) and G-H20 (Deionized water + PUI). After final irrigation protocols, all specimens were irrigated with phosphate buffer solution. Root canal obturation was performed using the single cone technique and Sealer Plus BC, stained with a specific fluorophore. Specimens were transversely sectioned and each root third was evaluated in a confocal scanning laser microscopy. Images obtained were analyzed for sealer penetration in the dentinal tubules. Results: Dentinal tubule penetration of Sealer Plus BC was not observed in any root third, regardless of the final irrigation protocol investigated. Conclusions: Sealer Plus BC dentinal tubule penetration was not observed after none of the protocols tested. Dentinal tubule penetrability of Sealer Plus BC may be related to other factors rather than the final irrigation protocol.


Subject(s)
Pit and Fissure Sealants , Pit and Fissure Sealants/therapeutic use , Dental Cements/therapeutic use , Sodium Hypochlorite/therapeutic use , Buffers , Bisphenol A-Glycidyl Methacrylate/analysis
15.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1484791

ABSTRACT

Abstract Background: The association of scaffolds to repair extensive bone defects can contribute to their evolution and morphophysiological recomposition. The incorporation of particulate biomaterials into three-dimensional fibrin bioproducts together with photobiomodulation therapy (PBM) has potential and can improve regenerative medicine procedures. The objective of this experiment was to evaluate the effects of PBM therapy on critical size defects filled with xenogenic bone substitute associated with fibrin biopolymer. Methods: A critical defect of 8 mm was performed in 36 Wistar male adult rats that were divided into four groups. Groups BC and BC-PBM were defined as controls with defects filled by a clot (without or with PBM, respectively) and groups XS and XS-PBM that comprised those filled with biocomplex Bio-OssTM in association with fibrin biopolymer. PBM was applied immediately after the surgery and three times a week every other day, with the parameters: wavelength of 830 nm, energy density 6.2 J/cm2, output power 30 mW, beam area of 0.116 cm2, irradiance 0.258,62 W/cm2, energy/point 0.72 J, total energy 2.88 J. Fourteen and 42 days after the surgery, animals were euthanatized and subjected to microtomography, qualitative and quantitative histological analysis. Results: The BC-PBM and XS-PBM groups had a similar evolution in the tissue repair process, with a higher density of the volume of new formed bone in relation to the groups without PBM (p = 0.04086; p = 0.07093, respectively). Intense vascular proliferation and bone deposition around the biomaterial particles were observed in the animals of the groups in which biocomplex was applied (XS and XS-PBM). Conclusion: PBM therapy allowed an improvement in the formation of new bone, with a more organized deposition of collagen fibers in the defect area. Biocomplex favored the insertion and permanence of the particulate material in bone defects, creating a favorable microenvironment for accelerate repair process.

16.
J. venom. anim. toxins incl. trop. dis ; 28: e20210056, 2022. tab, graf, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1360567

ABSTRACT

The association of scaffolds to repair extensive bone defects can contribute to their evolution and morphophysiological recomposition. The incorporation of particulate biomaterials into three-dimensional fibrin bioproducts together with photobiomodulation therapy (PBM) has potential and can improve regenerative medicine procedures. The objective of this experiment was to evaluate the effects of PBM therapy on critical size defects filled with xenogenic bone substitute associated with fibrin biopolymer. Methods: A critical defect of 8 mm was performed in 36 Wistar male adult rats that were divided into four groups. Groups BC and BC-PBM were defined as controls with defects filled by a clot (without or with PBM, respectively) and groups XS and XS-PBM that comprised those filled with biocomplex Bio-OssTM in association with fibrin biopolymer. PBM was applied immediately after the surgery and three times a week every other day, with the parameters: wavelength of 830 nm, energy density 6.2 J/cm2, output power 30 mW, beam area of 0.116 cm2, irradiance 0.258,62 W/cm2, energy/point 0.72 J, total energy 2.88 J. Fourteen and 42 days after the surgery, animals were euthanatized and subjected to microtomography, qualitative and quantitative histological analysis. Results: The BC-PBM and XS-PBM groups had a similar evolution in the tissue repair process, with a higher density of the volume of new formed bone in relation to the groups without PBM (p = 0.04086; p = 0.07093, respectively). Intense vascular proliferation and bone deposition around the biomaterial particles were observed in the animals of the groups in which biocomplex was applied (XS and XS-PBM). Conclusion: PBM therapy allowed an improvement in the formation of new bone, with a more organized deposition of collagen fibers in the defect area. Biocomplex favored the insertion and permanence of the particulate material in bone defects, creating a favorable microenvironment for accelerate repair process.(AU)


Subject(s)
Biocompatible Materials , Biopolymers , Collagen , Low-Level Light Therapy
17.
Braz. oral res. (Online) ; 36: e100, 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS, BBO | ID: biblio-1403959

ABSTRACT

Abstract This study aimed to evaluate physicochemical properties of three ready-to-use calcium silicate-based endodontic sealers: Endosequence BC Sealer, Bio C Sealer, and Sealer Plus BC. Radiopacity was evaluated using specimens of 10 mm in diameter and 1 mm in height, along with an aluminum step wedge. For the flow test, 0.5 mL of each sealer was deposited between glass plates and the mean of the measurement of two diameters was considered the cement flow value. For pH and calcium release, root canals of 30 prototypes of upper incisor acrylic resin teeth were filled with sealer and gutta percha point and then immersed in containers with 13 mL of ultrapure water. Both pH and release of calcium ions (atomic absorption spectrophotometer) were measured at 3, 24, 72, and 168 h. Acrylic resin teeth were scanned by Micro-CT 1174 at the time of pH and calcium ion readings for volumetric change analysis. The data were analyzed by ANOVA, Tukey's, Kruskal-Wallis, and Dunn's tests. Endosequence BC Sealer presented the lowest, and Bio C Sealer the highest volumetric change after 72 h and 168 h (p < 0.05). Endosequence BC Sealer presented higher radiopacity (p < 0.05). All materials showed alkalinization capacity. All of them presented calcium ion release, with a higher value for Sealer Plus BC. All materials presented alkalinization, calcium release capacity, radiopacity, and flow above the minimum values required by the ISO standard. The highest volumetric loss was experienced by Bio C Sealer and the lowest one by Endosequence BC Sealer.

18.
Braz. oral res. (Online) ; 36: e068, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1374736

ABSTRACT

Abstract: We aimed to evaluate the penetration of endodontic cement following the removal of calcium hydroxide (Ca(OH)2) dressing using the XP-endo Finisher in association with different irrigating solutions. Sixty premolars were instrumented and applied with a Ca(OH)2 dressing. To remove Ca(OH)2, the teeth were divided into six groups, each with a different volume of sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA), as well as solution stirring time with XP-endo Finisher (0, 30, and 60 sec). Root canals were filled using the lateral condensation technique. Fluorescein dye was added to the cement for microscopic laser scanning analysis. In the generated images, linear measurements were taken in micrometers, and their averages were calculated. To analyze the perimeter penetration ratio of the cement, the total perimeter of the canal and the segment of the total perimeter of the canal where the endodontic cement penetrated into the dentinal tubules were measured in micrometers. We found that using an XP-endo Finisher in irrigation was more effective than using a needle and syringe during the extension and penetration of endodontic cement. Shaking with XP-endo Finisher with 17% EDTA increased the extent and perimeter of the penetration of the endodontic cement into the dentinal tubules. However, using the XP-endo Finisher with EDTA only was more efficient than using the instrument interchangeably in NaOCl and EDTA. Although XP-endo Finisher contributes to the removal of Ca(OH)2, none of the protocols or instruments used removed all Ca(OH)2 from the root system.

19.
Braz. oral res. (Online) ; 36: e080, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384188

ABSTRACT

Abstract This study aimed to evaluate the root canal real length (RL) changes due to the mechanical instrumentation use with different flaring magnitudes. After access cavity, 60 mesial root canals of mandibular molars were randomly separated in three groups: Hyflex EDM (HF; #25/.12, #10/.05 e #25/~), Reciproc Blue (RB; R25), and MTwo (M2; #10/.04, #15/.05, #20/.06 e #25/.06). The RL was defined as the apical limit, and 2.5% sodium hypochlorite irrigating solution was chosen. After the access cavity (RL 1), cervical flaring (RL 2), and complete chemical-mechanical preparation (RL 3), the RL was evaluated. The RL was evaluated by a blind examiner with the aid of a microscope (16x) placing the endodontic file stop at the coronary reference. When comparing length measurements, the RL was shorter before instrumentation than that after instrumentation. A reduction of 0.65 mm (HF), 0.61 mm (RB), and 0.48 mm (M2) was observed. However, among groups, no statistical differences were found (p > 0.05). Under the conditions tested, it can be inferred that all mechanical systems provoked RL variations, which emphasizes the need for constant verification of the odontometry, mainly before root canal obturation.

20.
Braz. oral res. (Online) ; 36: e085, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384205

ABSTRACT

Abstract The aim of this study was to evaluate the quality of curved root canal preparation, torsional fatigue, and cyclic fatigue of rotary systems manufactured with different NiTi alloys. Ninety single-rooted canals with curvatures of 15° to 30o were scanned and divided into three groups according to the rotary system used: BT-Race (BTR) - 10.06, 35.00, 35.04; SequenceRotaryFile (SRF) - 15.04, 25.06, 35.04; and ProDesignLogic (PDL) - 25.01, 25.06, 35.05. Each system was used on three specimens. The teeth were prepared, scanned, and analyzed to assess increase in volume, transportation, and centering ability of the root canal. Torsional fatigue of glide path instruments (BTR 10.06, SRF 15.04 and PDL 25.01) and cyclic fatigue of the finishing instrument (BTR 35.04, SRF 35.04 and PDL 35.05) were obtained by analyzing completely new instruments (n = 10) and instruments after they had been used three times (n = 10). After the torsional and cyclic fatigue tests, the fractured surface of the new and used instruments were examined by scanning electron microscopy. Increase in volume, canal transportation, and centering ability showed no significant differences among the groups (p > 0.05). The torsional test showed that SRF 15.04 produced the highest torque values for both new and used instruments, followed by PDL 25.01 and BTR 10.06 (p < 0.05). PDL 25.01, both new and used, exhibited higher values of angular deflection followed by SRF 15.04 and BTR 10.06 (p < 0.05). As regards cyclic fatigue, use of PDL 35.05, both new and used, required a longer time and larger number of cycles than did SRF 35.04 and BTR 35.04 (p < 0.05). Clinical use affected the torsional fatigue of BTR; however, cyclic fatigue was not significantly affected (p < 0.05). All rotary systems were able to prepare the curved canals satisfactorily and were used safely on the three specimens. Relative to torsional fatigue, SRF 15.04 exhibited a higher torque, and PDL 25.01, higher angular deflection. BTR 10.06 was the most affected by clinical use. PDL 35.05 showed greater resistance to cyclic fatigue.

SELECTION OF CITATIONS
SEARCH DETAIL